Case:One HP ProLiant DL580 G7 server, 6* 300G SCSI hard disk RAID5, Windows operating system, file system is NTFS.There are two hard disks alarm, one piece of data is lost, one is … HPProLiantDL580G7 server raid5 damaged data loss recovery intoRead more
HPProLiantBL460cG7RAID Information Loss Server Data Recovery
Case:The server is RAID5 composed of 3 disks.The client calls the three plates, one plate and a plate of red lights, a plate of light, and the server cannot start. Solution:The company’s … HPProLiantBL460cG7RAID Information Loss Server Data RecoveryRead more
HPML370G4 server RAID0 data recovery succeeded
Case:The customer’s server is the HP ML370G4 server hard disk with a 2.5 -inch SAS interface with a total of 2 and a capacity of 146G.Run Windows Server 2003, the application system … HPML370G4 server RAID0 data recovery succeededRead more
HPML350G4 server RAID5 data recovery succeeded
Case:The customer’s server is the HP ML350G4 server. It was originally a RAID5 made of three 146G hard disks. The customer expanded three hard disks. It made a new set of RAID5 … HPML350G4 server RAID5 data recovery succeededRead more
HPLUN uninitialized data recovery succeeded
Case:HP EVA4400, 5*12 blocks 1T physical disk, all storage spaces form two Storage Group, allocating Lun about LUN: 9TB 1, 8TB of about 4, LUN mapped to two Windows Server.After the device … HPLUN uninitialized data recovery succeededRead more
The disk storage recovery of HPEVA6400144 hard disks was successful
Case:HP EVA6400 disk arrays, storage of a total of 144 1T hard disks. Earlier in the storage that cannot be used normally, Ungroup has 4 hard disks. After 4 hard disks are … The disk storage recovery of HPEVA6400144 hard disks was successfulRead more
HPEVA4400 server LUN fault recovery succeeded
Case:HP EVA4400, 5*12 blocks 1T physical disk, all storage spaces form two Storage Group, allocating Lun about LUN: 9TB 1, 8TB of about 4, LUN mapped to two Windows Server. Solution:Back up … HPEVA4400 server LUN fault recovery succeededRead more
HPDL580G7 server raid5 damaged hard disk alarm recovery successfully
Case:Customer’s HP Proliant DL580 G7 server, RAID5 made by 6* 300G SCSI hard disk, Windows operating system, file system is NTFS.There are two hard disks alarm, one piece of data is lost, … HPDL580G7 server raid5 damaged hard disk alarm recovery successfullyRead more
HPDL380G4+14 146GB array data recovery successfully
Case:A HP DL380 G4 server uses the HP Smart Array controller to mount a domestic disk array. The disk array consists of 14 146G SCSI hard disks.The operating system is Linux, which … HPDL380G4+14 146GB array data recovery successfullyRead more
HPDL380G7 server raid5 array crash server cannot start recovery
Case:A HP DL380 G7 server, RAID5 made by the 4*300G SAS hard disk, the customer did not replace the bright red light hard disk in time in normal use, which caused the … HPDL380G7 server raid5 array crash server cannot start recoveryRead more